5ESS Switch Output Message - OP:ILHB

OP:ILHB

Software Release: 5E14 and later 
   Command Group: MAINT
     Application: 5 
            Type: Output

Format

  1. OP ILHB DN=aaaaaaaaaa 
      DATE:bb/bb     TIME:cc:cc 
      LICDN=dddddddddd 
      MULT_CALL=e    PRIV_INC=f     TRACE=g     IDP=h 
      SCREENING=i    ADDR_TYPE=j    NUM_PLAN=k  UNIQ=l 
      CNPR_INC=m
    
  2. OP ILHB n     PTY=o 
      DATE:bb/bb     TIME:cc:cc 
      LICDN=dddddddddd 
      MULT_CALL=e    PRIV_INC=f     TRACE=g     IDP=h 
      SCREENING=i    ADDR_TYPE=j    NUM_PLAN=k  UNIQ=l 
      CNPR_INC=m
    
  3. OP ILHB DN=aaaaaaaaaa
      p
    
  4. OP ILHB n     PTY=o 
      p
    

Reason for Output

To report the Incoming Line History Block (ILHB) or an error message in response to an OP:ILHB input message.

Format 1 displays the ILHB status of a Directory Number (DN).

Format 2 displays the ILHB status of an Office Equipment (OE) number, which includes the following: an Integrated Digital Carrier Unit Line Equipment Number (ILEN), an Integrated Services Line Card Equipment Number (LCEN), a Line Equipment Number (LEN) of a line, an SLC Line Equipment Number (SLEN), or an Integrated Services Line Circuit (LCKEN).

Format 3 reports an error response for a DN.

Format 4 reports an error response for an OE number, which includes the following: an ILEN, a LCEN, a LEN, a SLEN, a LCKEN.

Variable Field Definitions

aaaaaaaaaa = Ten-digit directory number of the line.

b = Date of the last incoming call.  Listed in the form of month/day.

c = Time of day of the last incoming call.  Listed in the form of hour and minute.

dddddddddd = Last incoming calling DN.

e = Multiple call indicator.  Valid value(s):

f = Incoming privacy indicator (used for per-call privacy and all call privacy features).  Valid value(s):

g = Local Area Switching Services (LASS) Customer Originated Trace (COT) indicator.  Valid value(s):

h = Individual Dialing Plan (IDP) indicator.  Valid value(s):

i = LICDN screening indicator.  Valid value(s):

j = LICDN type of address.  Valid value(s):

k = LICDN numbering plan.  Valid value(s):

l = Uniqueness of the LICDN.  Valid value(s):

m = Calling name and calling number presentation indicator for the calling DN (the LICDN).  Valid value(s):

n = Valid value(s):

  1. ILEN=q-r-s-t (Integrated Line Equipment Number)
  2. LCEN=q-h1-i1-w (Line Card Equipment Number)
  3. LCKEN=q-h1-v-f1-g1 (Line Circuit Equipment Number)
  4. LEN=q-u-e1-y-z-a1 (Line Equipment Number)
  5. SLEN=q-b1-c1-d1 (SLC Line Equipment Number)

o = Party.  For an analog ILEN, LEN, LCEN, or SLEN, valid values are:

p = Error message in response to an OP:ILHB input message.  Valid value(s):

q = Switching Module (SM) number.

r = Integrated Digital Carrier Unit (IDCU) number.

s = Remote terminal (RT) number or IDCU Facility (IFAC) number.

t = RT line number or IFAC channel number.

u = Line unit number.

v = Line group number.

w = Line card number.

y = Switch board number.

z = Switch number.